Functions
Features
Includes
Specifications
• COSensor...................................... (KMCO1/Q)
O²Sensor................................................(OS11)
Flueprobeassembly....................... (KMCSP6)
ACadapter.................................... (KMCU110)
Filterbypass.............................................(FB1)
Replacementparticlefilter...................(16345)
Chemicalfilter...........................................(SF1)
Watertrap......................................(WTS9106)
Watertrapfilter.................................... (WN8)
Instructionmanual
• Expandablecapabilities,adduptofive
toxicgassensors
• 1926Memorylocationsfortestresults
(autoormanualrecording)
• Integratedplainpaperprinter
• Remoteoperationusing15’flueprobe
hoseand15’handsetcable
• Remotehandsetcablesavailablein30’
and60’lengths
• Long-life12Vsealedgelcellbattery
withACcharger
• Easyaccessparticlefilter,chemicalfilter,
andO²sensorforcustomerconvenience
KM9106/P
QUINTOX KM9106/P
Industrial Combustion
System Analyzer
Function Resolution Accuracy Range
Temperature 0.1˚F/C
±1˚F/C,±0.3%ofrdg 32˚~2140˚F
(0˚~1171˚C)
Gas Measurement
Oxygen 0.1% -0.1%/+0.2%
0-25%
Carbon Monoxide
Hydrogen
Compensated
1ppm ±20ppm<400ppm
±5%ofrdg<2000ppm
±10%ofrdg>2000ppm
0-10,000ppm
Carbon Dioxide
Calculated
0.1% ±0.30% 0~fuelvalue
Nitric Oxide
Nitrogen Dioxide
Sulphur Dioxide
1ppm ±5ppm<100ppm
±5%ofrdg>100ppm
Listedinoptional
section
Hydrocarbons 0.01%
<1%:±0.05%
>1%:±5%ofreading
Pressure (draft) 0.01mbar/inWG ±0.05%fullscale
KM9106 Optional Sensors
KMNO1/Q
NitricOxidesensor 0~5,000ppm
KMNO2/Q NitrogenDioxidesensor 0~1,000ppm
KMSO2/Q SulphurDioxidesensor 0~5,000ppm
KMHC104/Q Hydrocarbonsensor 0~5%LEL
KM6CO1/Q HighCO 0~10%
KMPS2/Q Pressuresensor(draft) 0~150mbar
Dimensions 17.75”longx9”widex13.75”high
Weight 21lbs.
Measures
• Oxygen(O²)0~25%
• Carbonmonoxide(CO)0~10,000ppm
(H²CompensatedandNOXfiltered)
• Inlettemperature
• Fluetemperature32~2140°F
(Optionalhightemperatureprobeshaft
forfluetemperaturesexceeding1112˚F)
Calculates
• Combustionefficiency,carbondioxide
(CO²),netstacktemperature,flue
losses,excessair,CO/CO²ratio,
andpoisonindex
INDUSTRIAL COMBUSTION ANALYZERS
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com